Lamp T529 for Ecosoft UV E-480

53.09  available on subscription

PARAMETERS

Maximum disinfected water flow 1.81 m³/h

Type of lamp T529

Max inlet pressure 8 atm

Electrical power of one emitter 29 W

Dimensions (length x diameter) 620×18 mm

Power supply 220 / 50 V / Hz

Neturime

KEY FEATURES

  • High dose of UV irradiation (30 mJ/cm2) sufficient to neutralize a wide spectrum of microorganisms
  • Physical method of disinfection that does not require chemicals or generate any toxic byproducts
  • Long efficient service life – up to 9 000 hours

SPECIFICATION

Performance

Replacement lamp T529 is mounted inside the body of ultravioletdisinfection unit Ecosoft E-480, where microorganisms decontamination occurs.

Technical data

  • Maximum disinfected water flow — 1.81 m³/hour
  • Type of lamp — T529
  • Maximum inlet pressure – 8 bar
  • Power supply — 230 V, 50 Hz
  • Power consumption of one lamp — 29 W
  • Appliance for lamp malfunction control — visual
  • Dimensions (length x diameter) — 620 × 18 mm

Feed water requirements

  • Temperature of the treated water — +4…+30 °С
  • Turbidity — 0.58 mg/L
  • Total hardness — 2.5 meq/L
  • Iron — 0.3 mg/L
  • Manganese — 0.05 mg/L
  • Hydrogen sulfide — 0.05 mg/L