Water Specialist 2” CE Downflow Regeneration Control Valves ( without meter ) (EN)

1 ,536.00  available on subscription

Neturime

KEY FEATURES

  • Multilanguage menu: English, German, French, Ukrainian
  • User friendly and Auto settings. Pre-set programms for Ecomix units and softeners
  • Mixing valve option available
  • Downflow regeneration
  • Backlit screen (high useful for dark environment)
  • Text menu settings
  • Manual and flexible setting of regenetation
  • Programmable regeneration cycle times
  • Water consumption memory in 124 days
  • Additional relay and MAV/NHBP outputs for complicated projects
  • 24-hour clock

SPECIFICATION

Specifications

Inlet/Outlet (1) – 2” Female BSPT or NPT

Cycles – up to 9

Valve Material – Lead free brass

Regeneration – Downflow

CONTROL VALVE FLOW RATES

Service @ 15 psi/1 bar drop (includes bypass and meter) – 435 lpm (26.1 m3/h) (115 gpm)

Backwash @ 25 psi/1.7 bar drop – 303 lpm (18.2 m3/h) (80 gpm)

Cv Service – 29.7

Cv Backwash – 16.0

OPERATING PRESSURES

Minimum/Maximum: 20 – 125 psi (1.4 – 8.6 bar)

OPERATING TEMPERATURES

Minimum/Maximum: 40º – 110º F (4º – 43º C)

METER

Accuracy: ± 5%

Flow Rate Range: 5.7 – 568 lpm (1.5 – 150 gpm)

Volume Range: 0.02 – 5,700 m3

Totalizer: 1 m3 – 99,999 m3 (264 – 26,417,000 gallons)

DIMENSIONS & WEIGHT

Distributor Pilot

    Valve bodies with 2″ Female BSPT Inlet & Outlet – 50 mm OD

    Valve bodies with 2″ Female NPT Inlet & Outlet – 1.90” OD (1.5″ NPS)

Drain Line Connection – 1.5” Female NPT

Brine Line Adapters Included – 1” Male NPT elbow, ¾” x 1” solvent weld elbow and 1⁄2″ OD Poly Tube Compression

Mounting Base – 4″ – 8 UN

Height From Top Of Tank – 216 mm (8.5”)

Shipping Weight With Meter – 13 Kg (29 lbs.)

ELECTRICAL SPECIFICATIONS
POWER SUPPLY
 
  U.S. International
Supply Voltage 100VAC to 120VAC
200VAC to 240VAC
Supply Frequency 50/60 Hz 50/60 Hz
Output Voltage 15VDC 15VDC
Output Current 500 mA 500 mA

TANK APPLICATIONS

Water Softener: 6″ – 48″ Diameter

Water Filter (3): 6″ – 36″ Diameter

CYCLES OF OPERATION

Choose up to nine regeneration cycles, in any order, with a wide range of available values:

Backwash: 1 – 120 minutes

Rinse: 1 – 120 minutes

Pause (service): 1 – 480 minutes

Brine (co-current): 1 – 180 minutes

Refill (softener): 0.05 – 90.00 Kg / .1 – 99 minutes

Refill (filter): 0.2 – 76.00 Liters

Options: Backwash Filter, Bypass, Weather Cover

Compatible with the following typical concentrations of regenerants or chemicals: Sodium chloride, potassiumchloride, potassium permanganate, sodium bisulfite, chlorine and chloramines

(1) Filter tank size calculated @ 10 gpm of backwash per square foot of bed area / 407 lpm per square meter of bed area